Offering you a complete choice of products which include hioki dt4255 digital multimeter, digital multimeter dt4261, digital multimeter dt4252, digital multimeter dt4256, digital multimeter dt4281 and hioki dt4253 digital multimeter.
₹ 9923 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4255 |
| Features | Digital Multimeter with Fuse-protected Terminals Ideal for Harsh Work Environments |
| AUTO AC/DCV | Yes |
| DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. |
|||||
|---|---|---|---|---|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
|||||
| AUTO AC/DCV | Yes | |||||
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. | |||||
| DC Current range | N/A | |||||
| From 4 to 20mA Percentage conversion display | N/A | |||||
| AC Current range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) | |||||
| Temperature (thermocouples) |
N/A | |||||
| Voltage detection | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V | |||||
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. | |||||
| Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
|||||
| Continuity check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
|||||
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
|||||
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) | |||||
| Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) | |||||
₹ 17455 / Piece Get Latest Price
| Current Rating | 600.0 mA to 10.00 A, 3 ranges Basic accuracy 40 Hz - 500 Hz: +-1.4% rdg. +-3 dgt. (True RMS, crest f |
| Brand | hioki |
| Model Name/Number | dt 4261 |
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges, Basic accuracy: +-0.15% rdg. +-2 dgt. |
| ac current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy 40 Hz - 500 Hz: +-1.4% rdg. +-3 dgt. (True RMS, crest fac |
| diode test | Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: |
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 Hz - 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
| DC + AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| LoZ V | 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt. |
| DC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy: ±0.5% rdg. ±3 dgt. |
| AC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy 40 Hz - 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less) Frequency characteristics: 40 Hz to 1 kHz |
| AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Continuity Check | Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more |
₹ 11800 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4252 |
| Features | General Purpose Testers with Rich Measurement Functions |
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±5 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV | N/A |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt. |
| DC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±0.9 % rdg. ±5 dgt. |
| AC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
| AC Current range (use with Clamp on probes) | N/A |
| Voltage detection (50/60 Hz) | N/A |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
| Frequency range | AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V) Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| Continuity check | Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more Response time: 0.5 ms or more |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) |
| Display | Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph |
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (back light OFF) |
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (with batteries and holster) |
| Included accessories | Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 * Replaced by the probe L9300 starting with batches manufactured in March, 2025. |
₹ 12840 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4256 |
| Features | Standard DMM that Delivers Top Safety and Reliability - General Purpose Testers with Rich Measuremen |
| Country | Japan |
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. |
|||||
|---|---|---|---|---|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
|||||
| AUTO AC/DCV | Yes | |||||
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. | |||||
| DC Current range | 60.00 mA to 10.00 A, 4 ranges, Basic accuracy: ±0.9 % rdg. ±3 dgt. |
|||||
| AC Current range | 600.0 mA to 10.00 A, 3 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
|||||
| AC Current range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) | |||||
| Voltage detection (50/60 Hz) |
Hi: AC40 V to 600 V, Lo: AC80 V to 600 V | |||||
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. | |||||
| Frequency range | 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current), | |||||
₹ 29999 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4281 |
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) |
| Continuity Check | Continuity threshold: 20/50/100/500 , Response time: 10 ms or more |
| DC Voltage range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | |||||
|---|---|---|---|---|---|---|
| AC Voltage(*1) range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|||||
| DC + AC Voltage(*1) range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|||||
| Resistance range | 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt. | |||||
| DC Current range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.05 % rdg. ±5 dgt. |
|||||
| AC Current(*1) range | 600.00 μA to 600.00 mA, 4 ranges Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
|||||
| AC Current(*1) range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges Add the Clamp on probe accuracy to Basic accuracy 40 - 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3) |
|||||
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|||||
| Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. | |||||
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more | |||||
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages | |||||
₹ 17400 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4253 |
| Features | Standard DMM that Delivers Top Safety and Reliability - Testing for Heating, Ventilation and Air Con |
| From 4 to 20mA Percentage conversion display | Yes |
| DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±5 dgt. |
|||||
|---|---|---|---|---|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
|||||
| AUTO AC/DCV | Yes | |||||
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt. | |||||
| DC Current range | 60.00 μA to 60.00 mA, 4 ranges, Basic accuracy: ±0.8 % rdg. ±5 dgt. |
|||||
| From 4 to 20mA Percentage conversion display | Yes | |||||
| AC Current range (use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) | |||||
| Temperature (thermocouples) |
K: -40.0 to 400.0 °C , Add the Temperature probe accuracy to basic accuracy: ±0.5 % rdg. ±2 °C | |||||
| Voltage detection | N/A | |||||
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. | |||||
| Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
|||||
| Continuity check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
|||||
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
|||||
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option), 4-20 mA percentage conversion | |||||
| Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph | |||||
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) | |||||
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) | |||||
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
|||||
| Included accessories | Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 * Replaced by the probe L9300 starting with batches manufactured in March, 2025. |
|||||
₹ 32880 / Piece Get Latest Price
| Current Rating | 600A |
| Brand | Hioki |
| Model Name/Number | DT4282 |
| Features | The ultimate digital multimeter, ideal for use R&D applications |
| Measure ripple voltage of DC charging systems | You can measure ripple voltage with a superposed DC signal by using peak value measurement and DC + |
| DC Voltage range | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. | |||||
|---|---|---|---|---|---|---|
| AC Voltage(*1) range | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|||||
| DC + AC Voltage(*1) range | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|||||
| Resistance range | 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only) Basic accuracy: ±0.03 % rdg. ±2 dgt. |
|||||
| DC Current range | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. | |||||
| AC Current(*1) range | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
|||||
| AC Current(*1) range (use with Clamp on probes) |
N/A | |||||
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|||||
| Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. | |||||
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more | |||||
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages | |||||
| Frequency range | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
|||||
| dB conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV) |
|||||
| Temperature (thermocouples) |
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C |
|||||
| Other functions | Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion | |||||
Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India