Our range of products include hioki pq3198 power quality analyzer and hioki pq3100 power quality analyzer.
₹ 638549 / Piece Get Latest Price
| Model Name/Number | PQ3198 |
| Usage/Application | Industrial Use |
| Display Type | Digital |
| Phase | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra in |
| Color | Blue |
| Dimension | 300 mm (11.81 in)W x 211 mm (8.31 in)H x 68 mm (2.68 in)D, 2.6 kg (91.7 oz) (including Battery Pack |
| Interfaces | SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication) |
| Brand | Hioki |
| Record | Repeated ON: 1 year, Maximum recording event: 9999 x 366 days (up to 9999 events per day) |
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) |
| Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement) | |||||
|---|---|---|---|---|---|---|
| Voltage ranges | Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak |
|||||
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) | |||||
| Power ranges | 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use) | |||||
| Basic accuracy | Voltage: ±0.1% of nominal voltage Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy |
|||||
| Measurement items | 1. Transient voltage : 2 MHz sampling 2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle Current (1/2) RMS: half-cycle calculation 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz 9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz 10. Voltage waveform peak, Current waveform peak 11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency 12. High-order harmonic* component (voltage/ current): 2 kHz to 80 kHz *Supraharmonic 13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders 14. Harmonic voltage-current phase angle: 1th to 50 th orders 15. Total harmonic distortion factor (voltage/ current) 16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order 17. K Factor (multiplication factor) 18. IEC Flicker, Δ V10 Flicker 19. Mains signaling voltage |
|||||
₹ 450000 / Piece Get Latest Price
| Model Name/Number | PQ3100 |
| Usage/Application | Industrial Use |
| Display Type | Digital |
| Phase | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra in |
| Interfaces | SD/SDHC memory card, RS-232C (for communication/ LR8410 link), LAN (HTTP server/ FTP/ Send e-mail) |
| Voltage | AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous |
| Brand | Hioki |
| Display | 6.5-inch TFT color LCD (640 x 480 dots) |
| Record | Maximum recording interval: 1 year, Maximum number of recordable events: 9999 x 365 days |
| Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement) | |||||
|---|---|---|---|---|---|---|
| Voltage ranges | Voltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak | |||||
| Current ranges | 50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC (depends on current sensor in use) |
|||||
| Power ranges | 50.000 W to 6.0000 MW (determined automatically based on current range in use) | |||||
| Basic accuracy | Voltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy | |||||
| Measurement items | 1. Transient over voltage : 200 kHz sampling 2. Frequency cycle : Calculated as one cycle 3. Voltage (1/2) RMS, Current (1/2) RMS: one cycle calculation refreshed every half cycle 4. Voltage swell, Voltage dips, Voltage interruption, RVC (Ver.2.0 or later) : Voltage (1/2) RMS calculation 5. Inrush current : half-cycle calculation: Calculated as the current RMS value for current waveform data sampled every half-cycle. 6. Frequency 200 ms: Calculated as 10 or 12 cycles 7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period 8. Voltage waveform peak, Current waveform peak 9. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Energy cost, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor 10. Voltage crest factor, Current crest factor 11. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0 th to 50 th orders 12. Harmonic voltage-current phase angle: 1 th to 50 th orders 13. Total harmonic distortion factor (voltage/ current) 14. Inter harmonic (voltage/ current): 0.5 th to 49.5 th orders 15. K Factor (multiplication factor) 16. IEC Flicker, Δ V10 Flicker |
|||||