Providing you the best range of hioki pw3365 clamp on power logger, hioki pw3360 clamp on power logger, hioki sf1001 power logger viewer and hoiki m7103 power measurement module with effective & timely delivery.
₹ 180000 / Piece Get Latest Price
| Interface | Digital |
| Power Supply | 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type) |
| Memory | SD/SDHC Memory card, or internal memory at real time |
| Warranty | 1 year |
| Features | Display clamp-on power logger measurement results as a graph so you can review them at a glance |
| Measurement line & number of circuits | 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels | |||||
|---|---|---|---|---|---|---|
| Measurement items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand | |||||
| Voltage ranges | 400 V AC (Effective measurement range: 90.0 V to 520.0 V) | |||||
| Harmonic | Harmonic voltage, harmonic current, voltage total harmonic distortion (THD-F or THD-R), current total harmonic distortion (THD-F or TDH-R), up to 13th order | |||||
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) |
|||||
| Power ranges | 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type) | |||||
| Basic accuracy | Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020) Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1) |
|||||
| Display update rate | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) | |||||
| Save destination | SD/SDHC Memory card, or internal memory at real time | |||||
| Data save interval | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections | |||||
₹ 147000 / Piece Get Latest Price
| Interface | Digital |
| Power Supply | AC adapter Z1008: (100 to 240 V AC, 50 Hz/60 Hz), 45 VA (including AC adapter) |
| Memory | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections |
| Warranty | 1 year |
| Features | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) |
Minimum order quantity: 14 Piece
| Measurement line & number of circuits | 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels | |||||
|---|---|---|---|---|---|---|
| Measurement items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input [PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order |
|||||
| Voltage ranges | 600 V AC (Effective measurement range: 90.00 V to 780.00 V) | |||||
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) |
|||||
| Power ranges | 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type) | |||||
| Basic accuracy | Voltage : ±0.3% rdg. ±0.1% f.s Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1) |
|||||
| Display update rate | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) | |||||
| Save destination | SD memory card, or internal memory at real time | |||||
| Data save interval | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections | |||||
| Save items | Measurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data | |||||
₹ 36000 / Piece Get Latest Price
| Brand | Hioki |
| Model | SF1001 |
| Supported Computer Os | Computer Running Under Windows 10 |
| Copy Function | Captures Any Display Image To The Clipboard |
| Waveform Display | Displays Waveform Data At Specified Data |
| Report Printing | Print Contents Over A Specific Time Period |
Hioki portable power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The SF1001 is a software application for graphing measurement data captured with the PW3360/3365 series, 3169 series Clamp On Power Loggers using a computer.
Get Latest Price
| Operating Voltage | 24V |
| Brand | Hoiki |
| Model Name/Number | M7103 |
| Number Of Power Channels | 3 |
| Current Range | 0.04 A To 20 KA |
| Crest Factor | 3 ut 1.35 For 1500 V Range |
| Maximum Input Voltage | 1000 V AC, 2000 V DC |
| Effective Measurement Range | 1% To 110% of range |
| Dimensions | 65W x 170H x 255D mm |
| Weight | 1.5 Kg |
| Functions | Auto Range, Calculation, Synchronization Source Sharing |
Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India