Our product range includes a wide range of hioki 9322 differential probe, hioki p9000 differential probe, hioki mr8790 waveform generator unit, hioki u8793 arbitrary waveform generator, hioki sp7001, sp7002 non contact can sensor and hioki 9320-01 logic probe.

Hioki 9322 Differential Probe

Request Callback

₹ 65000 / Piece Get Latest Price

Product Brochure
OutputVoltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output)
accessoriesAlligator clips x1 (red/black set), Grabber Clip L9243 x1 (red/black set), Carrying case C0203 x1, I
inputAlligator clips x1 (red/black set), Grabber Clip L9243 x1 (red/black set), Carrying case C0203 x1, I
Power Supply+5 V to +12 V, less than 300 mA (DC jack OD 5.5 mm [0.22 in.], ID 2.1 mm [0.08 in.])
FunctionDC mode: Waveform monitor output, DC to 10 MHz +-3 dB AC mode: Detection of power line surge noise, 1
3 Kinds of Measurements with a Single Probe





Accuracy guaranteed: 1 year
*1: Discontinued product
Measurement functions DC mode: Waveform monitor output, DC to 10 MHz ±3 dB
AC mode: Detection of power line surge noise, 1 kHz to 10 MHz ±3 dB
(Low frequency cut-off frequency 1 kHz ± 300 Hz)
RMS mode: Rectified RMS output of DC and AC voltages, DC, 40 Hz to 100 kHz, Response speed: 200 ms or less (400 V AC)
Max. allowable input 2000 V DC, 1000 V AC
Max. rated voltage to earth When using the Grabber Clip L9243: 1000 V AC/DC (CAT II)
When using alligator clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III)
Output Voltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output)
DC amplitude accuracy ±1 % f.s. (1000 V DC or less), ±3 % f.s. (2000 V DC or less) (f.s.=2000 V DC)
RMS amplitude accuracy ±1 % f.s. (DC, 40 Hz to 1 kHz), ±4 % f.s. (1 kHz to 100 kHz) (f.s.=1000 VAC)
Input resistance, capacity H-L: 9 MΩ, approx 10 pF (C at 100 kHz)
H-case, L-case: 4.5 MΩ, approx 20 pF (C at 100 kHz)
Power supply +5 V to +12 V, less than 300 mA (DC jack OD 5.5 mm [0.22 in.], ID 2.1 mm [0.08 in.])

- Via AC Adapter 9418-15
- Via MR6000 dedicated Probe Power Unit Z5021 through Power Cord 9248
- Via Logic terminal on Memory HiCorder through Power Cord 9324 (*1)
- Via sensor terminal of F/V Unit 8940 (*1) through Power Cord 9325 (*1)
- Via DC power output terminal attached to the input unit for the 8855 through Power Cord 9328 (*1)
- Via the 8860 series dedicated Probe Power Unit 9687 (*1) through Power Cord 9248
Dimensions and mass 70 mm (2.76 in)W × 150 mm (5.91 in)H × 25 mm (0.98 in)D, 350 g (12.3 oz), Cord length: Input 46 cm (1.51 ft), Output 1.3 m (4.27 ft)
Included accessories Alligator clips ×1 (red/black set), Grabber Clip L9243 ×1 (red/black set), Carrying case C0203 ×1, Instruction manual ×1
How to power the 9322 with a Hioki Memory HiCorder (Via MR6000 dedicated Probe Power Unit Z5021)Precaution: To avoid electric shock, connect the power cord supplied with the main unit (Memory HiCorder or AC adapter for the 9322) to a grounded 2-pole outlet.
*3: When a current sensor is connected to the Probe Power Unit Z5021, or the Current Unit 8971, U8977, the number of the 9322 connection including the current sensor is limited (up to a total of 9 including the current sensor).
Main unit Number of the 9322 connections
MR6000
MR6000-01
8 (Combined with 9248 cable) (*3)



,

Hioki P9000 Differential Probe

Request Callback

₹ 52920 / Piece Get Latest Price

Product Brochure
BrandHioki
Pin Size8 mm
Frequency4 MHz
ColorBlack
Usage/ApplicationIndustrial
MaterialStainless Steel

Minimum order quantity: 10 Piece

Accuracy guaranteed: 1 year
P9000-01 P9000-02
Measurement functions Waveform monitor output only
Frequency characteristics: DC to 100 kHz, -3 dB
Waveform monitor output/AC RMS value output (switchable)
Wave mode frequency characteristics: DC to 100 kHz, -3 dB
RMS mode frequency characteristics: 30 Hz to 10 kHz; response time: 300 ms (rising) or 500 ms (falling)
Division ratio 1000:1 or 100:1 (user selectable)
DC amplitude accuracy ±0.5% f.s. (f.s. = 1.0 V; voltage division ratio: 1000:1) (f.s. = 3.5 V; voltage division ratio: 100:1)
RMS amplitude accuracy n/a ±1% f.s. (30 Hz to 1 kHz non-inclusive, sine wave), ±3% f.s. (1 kHz to 10 kHz, sine wave)
Input resistance, capacity Between H and L: 10.5 MΩ, 5 pF or less (at 100 kHz)
Max. allowable input 1000 V AC/DC
Max. rated voltage to earth 1000 V AC/DC (CAT III)
Operating temperature -40˚C (-40˚F) to 80˚C (176˚F)
Power supply (1) AC Adapter Z1008 (100 to 240 V AC, 50/60 Hz), 6 VA (including AC adapter) or 0.9 VA (probe only)
(2) USB bus power (5 V DC, USB Micro-B receptacle), 0.8 VA
To prevent an electric shock, when supplying power from the USB-microB terminal, please supply from a device which USB's GND terminal of the source device is grounded.
(3) External power supply (2.7 V to 15 V DC)
Dimensions and mass 128 mm (5.04 in)W × 36 mm (1.42 in)H × 22 mm (0.87 in)D, 170 g (6.0 oz), Cord length: Input: 70 cm (2.30 ft) ; output: 1.5 m (4.92 ft)
Included accessories Instruction manual ×1, alligator clips ×2, carrying case ×1
Number of P9000 probes that can be used when power is supplied from the standard USB terminal of the Memory HiCorder(Caution 1) To prevent an electric shock, connect the power cord supplied with the main unit (Memory HiCorder or AC adapter for the P9000) to a grounded 2-pole outlet.
(Caution 2) Custom-order 3-branch cable cannot be used with the standard USB terminal of the main unit (Memory HiCorder).
Main unit Number of the P9000-01, P9000-02 connections
MR8880 1
MR8875 1
MR8847A 1
MR8827 2
MR8740 2
MR8741 2
MR8740T 8
MR6000, MR6000-01 6
(The USB terminal in the media box of MR6000 cannot be used)

Hioki MR8790 Waveform Generator Unit

Request Callback

₹ 176800 / Piece Get Latest Price

Product Brochure
Frequency160 MHz
Max. output current5 mA
Output functionDC, Sine wave (Output frequency range: 1 Hz to 20 kHz)
Dimensions and mass106 mm (4.17 in) W x 19.8 mm (0.78 in) H x 196.5 mm (7.74 in) D, 230 g (8.1 oz)
Output voltage range-10 V to 10 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
Accuracy guaranteed: 1 year
Output terminal Number of channels: 4, SMB terminal (Output impedance: 1 Ω or less)
Max. rated voltage to ground: 30 V rms AC or 60 V DC
Output voltage range -10 V to 10 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
Max. output current 5 mA
Output function DC, Sine wave (Output frequency range: 1 Hz to 20 kHz)
Accuracy Amplitude accuracy: ±0.25% of setting ±2 mV p-p (1 Hz to 10 kHz)
Offset accuracy: ±3 mV
DC output accuracy: ±0.6 mV
Other Self-test function (Voltage, Current)
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 230 g (8.1 oz)
Included accessories None

Hioki U8793 Arbitrary Waveform Generator

Request Callback

₹ 236494 / Piece Get Latest Price

Product Brochure
Frequency350 MHz
Dimensions and mass106 mm (4.17 in) W x 19.8 mm (0.78 in) H x 196.5 mm (7.74 in) D, 250 g (8.8 oz)
Program functionMax. 128 steps (Number of loops for each step, Number of total loops)
Sweep functionFrequency, Amplitude, Offset, Duty (Pulse only)
Arbitrary waveform generator modeWaveforms measured by MR8847A, etc., generated by Hioki Model 7075, PQ3198, or SF8000, CSV waveforms
Function generatorDC, Sine wave, Square wave, Pulse wave, Triangular wave, Ramp wave, Output frequency: 10 mHz to 100

Minimum order quantity: 10 Piece

Accuracy guaranteed: 1 year
Output terminal Number of channels: 2, SMB terminal (Output impedance: 1 Ω or less)
Max. rated voltage to ground: 30 V rms AC or 60 V DC
Output voltage range -10 V to 15 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
Max. output current 10 mA (Allowable load resistance: 1.5 kΩ or more)
Function generator DC, Sine wave, Square wave, Pulse wave, Triangular wave, Ramp wave, Output frequency: 10 mHz to 100 kHz
Arbitrary waveform generator mode Waveforms measured by MR8847A, etc., generated by Hioki Model 7075, PQ3198, or SF8000, CSV waveforms
D/A refresh rate: 2 MHz (using 16-bit D/A)
Sweep function Frequency, Amplitude, Offset, Duty (Pulse only)
Program function Max. 128 steps (Number of loops for each step, Number of total loops)
Other Self-test function (Voltage), External input/output control
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 250 g (8.8 oz)
Included accessories None

Hioki SP7001, SP7002 Non Contact Can Sensor

Request Callback

₹ 90500 / Piece Get Latest Price

Product Brochure
Range0.5 kV
Model Name/NumberNON-CONTACT CAN SENSOR SP7001, SP7002 price
Voltage100 V to 240 V
BrandHIOKI
Detection methodCapacitive-coupled signal detection No bare-wire connections
Detectable cablesAVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in)
Number of channels1 CH (SP7150), 2 CH (SP7100)

Minimum order quantity: 10 Piece

Basic specifications
Detection method Capacitive-coupled signal detection
No bare-wire connections
Detectable cables AVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in)
Number of channels 1 CH (SP7150), 2 CH (SP7100)
Compatible communications speeds SP7001: CAN, CAN FD 125 kbit/s to 3 Mbit/s
SP7002: CAN 125 kbit/s to 1 Mbit/s
Total delay time 130 ns (typical)
CAN terminal resistance 60 Ω (typical), built-in
Signal output connector D-sub 9-pin female
Operating temperature, humidity Temperature: -40 °C to 85 °C (-40 °F to 185 °F)
Humidity: -40 °C to 60 °C (-40 °F to 140 °F), 80% RH or less (with no condensation), 60 °C to 85 °C (140 °F to 185 °F), 60% RH or less (with no condensation)
Power supply (1) When using the SP7001-95 or SP7150
- USB bus power (5 V DC), Maximum rated power: 8 VA
- Z1013 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 6 VA (including AC adapter), 1 VA (product only)

(2) When using the SP7001-90, SP7002-90, or SP7100
- Z1008 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 8 VA (including AC adapter), 3 VA (product only)
- External power supply: Rated supply voltage: 10 V to 30 V DC, Maximum rated power: 3 VA
Dimensions and mass (*1) SP7001, SP7002: 44 W × 85 H × 20 D mm (1.73 in. W × 3.35 in. H × 0.79 in. D), 180 g (6.35 oz.), Cable length: 2.5 m (8.20 ft.)
SP7100: 55 W × 120 H × 25 D mm (2.17 in. W × 4.72 in. H × 0.98 in. D),130 g (4.59 oz.), Cable length: 0.3 m (0.98 ft.)
SP7150: 47 W × 100 H × 20 D mm (1.85 in. W × 3.94 in. H × 0.79 in. D),100 g (3.52 oz.), Cable length: 0.3 m (0.98 ft.)
SP9250:10.5 W × 24.5 H × 101 D mm (0.41 in. W × 0.96 in. H × 3.98 in. D),45 g (1.59 oz.), Cable length: 0.8 m (2.62 ft.)
SP9200: φ11.6 × 33.7 H mm (φ0.46 in. × 1.33 in.), 26 g (0.92 oz.), Cable length: 0.5 m (1.64 ft.)
Included accessories (SP7001, SP7002) Quick Start Manual ×1, Operating Precautions ×1
Included accessories (SP7100) Quick Start Manual ×1, Operating Precautions ×1, Spiral tube ×1, Power cable L9500 ×1, Alligator clip ×1, Ground connection cable ×1
Included accessories (SP7150) Quick Start Manual ×1, Operating Precautions ×1, Spiral tube (for fixing power cable) ×1, USB Cable L9510 ×1, Ground connection cable ×1, Alligator clip ×1
  • *1:Dimensions do not include cables. Mass includes cables.

Hioki 9320-01 Logic Probe

Request Callback

₹ 36000 / Piece Get Latest Price

Product Brochure
Brandhoiki
Model Name/Number9320-01
accessoriesIC clip leads x1, Alligator clip leads x1, Carrying case x1, Instruction Manual x1
Pulse Width500 ns or longer
FunctionDetection of voltage signal or relay contact signal for High/Low state recording
Note: The unit-side plug of the 9320-01 is different from the 9320
Function Detection of voltage signal or relay contact signal for High/Low state recording
Input 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals)
Input resistance: 1 MΩ (with digital input, 0 to +5 V)
500 kΩ or more (with digital input, +5 to +50V)
Pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V)
Digital input threshold 1.4V/ 2.5V/ 4.0V
Contact input detection resistance 1.4 V: 1.5 kΩ or higher (open) and 500 Ω or lower (short)
2.5 V: 3.5 kΩ or higher (open) and 1.5 kΩ or lower (short)
4.0 V: 25 kΩ or higher (open) and 8 kΩ or lower (short)
Detectable pulse width 500 ns or longer
Max. allowable input 0 to +50V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass 62 mm (2.44 in)W × 94 mm (3.70 in)H × 20 mm (0.79 in)D, 150 g (5.3 oz), Main unit cable 1.5 m (4.92 ft), input section cable 300 mm (0.98 ft)
Included accessories IC clip leads ×1, Alligator clip leads ×1, Carrying case ×1, Instruction Manual ×1

Hioki MR8791 Pulse Generator

Request Callback

₹ 99000 / Piece Get Latest Price

Product Brochure
Automation GradeFully Automatic
Voltage120-240v
BrandHioki
Dimensions and mass106 mm (4.17 in) W x 19.8 mm (0.78 in) H x 196.5 mm (7.74 in) D, 230 g (8.1 oz)
Output terminalNumber of channels: 8, Connector: D-sub, half-pitch, 50-pin

Minimum order quantity: 10 Piece

Accuracy guaranteed: 1 year
Output terminal Number of channels: 8, Connector: D-sub, half-pitch, 50-pin
Max. rated voltage to ground: 30 V rms AC or 60 V DC (between unit and output channels)
Logic output/Open collector output
Output mode 1 Pattern output: Read frequency: 10 Hz to 120 kHz, 2048 logic patterns
Pulse output: Frequency 0.1 Hz to 20 kHz, Duty 0.1% to 99.9%
Output mode 2 Logic output: Output voltage level: 0 V to 5 V
(H level: 3.8 V or more, L level: 0.8 V or less)
Open collector output: Absolute maximum rated voltage for collector/emitter: 50 V
Overcurrent protection: 100 mA
Other Self-test function
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 230 g (8.1 oz)
Included accessories None

Hioki 9327 Logic Probe

Request Callback

₹ 41145 / Piece Get Latest Price

Brandhioki
Model Name/NumberLOGIC PROBE 9327
Power Consumptionelectric
Note: The unit-side plug is miniature terminal type
Function Detection of voltage signal or relay contact signal for High/Low state recording
Input 4 channels (common ground between unit and channels), digital/contact input, switchable (contact input can detect open-collector signals)
Input resistance: 1 MΩ (with digital input, 0 to +5 V)
500 kΩ or more (with digital input, +5 to +50V)
Pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V)
Digital input threshold 1.4V/ 2.5V/ 4.0V
Contact input detection resistance 1.4 V: 1.5 kΩ or higher (open) and 500 Ω or lower (short)
2.5 V: 3.5 kΩ or higher (open) and 1.5 kΩ or lower (short)
4.0 V: 25 kΩ or higher (open) and 8 kΩ or lower (short)
Detectable pulse width 100 ns or longer
Max. allowable input 0 to +50V DC (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass 62 mm (2.44 in)W × 94 mm (3.70 in)H × 20 mm (0.79 in)D, 150 g (5.3 oz), Main unit cable 1.5 m (4.92 ft), input section cable 300 mm (0.98 ft)
Included accessories IC clip leads ×1, Alligator clip leads ×1, Carrying case ×1, Instruction Manual ×1

Hioki MR9321-01 Logic Probe

Request Callback

₹ 36588 / Piece Get Latest Price

BrandHIOKI
Model Name/NumberMR9321-01
Output (L) detection0 to 30 V AC, +-DC 0 to 43 V (HIGH range)
Included accessoriesCarrying case x1, Instruction Manual x1
Max. allowable input250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage that can be applied across input pi

Minimum order quantity: 10 Piece

Note: The unit-side plug of the MR9321-01 is different from the MR9321.
Function Detection of AC or DC relay drive signal for High/Low state recording
Can also be used for power line interruption detection
Input 4 channels (isolated between unit and channels), HIGH/LOW range switching
Input resistance: 100 kΩ or higher (HIGH range), 30 kΩ or higher (LOW range)
Output (H) detection 170 to 250 V AC, ±DC 70 to 250 V (HIGH range)
60 to 150 V AC, ±DC 20 to 150 V (LOW range)
Output (L) detection 0 to 30 V AC, ±DC 0 to 43 V (HIGH range)
0 to 10 V AC, ±DC 0 to 15 V (LOW range)
Response time Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range at 200 V DC, LOW range at 100 V DC)
Max. allowable input 250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage that can be applied across input pins without damage)
Dimensions and mass 62 mm (2.44 in)W × 128 mm (5.04 in)H × 20 mm (0.79 in)D, MR9321-01: 300 g (10.6 oz), MR9321: 320 g (11.3 oz), Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft)
Included accessories Carrying case ×1, Instruction Manual ×1

Hioki U8794 Vir Generator Unit

Request Callback

₹ 386533 / Piece Get Latest Price

Product Brochure
PhaseThree Phase
Input Voltage380 V AC
Country of OriginMade in India
Output itemsDC voltage, DC current, resistance (simulated output)
Dimensions and mass106 mm (4.17 in) W x 19.8 mm (0.78 in) H x 196.5 mm (7.74 in) D, 280 g (9.9 oz)
Basic specificationsAccuracy guaranteed: 1 year
Output terminal Number of channels: 8 (each channel is isolated), Connector: 25-pin D-sub
Max. rated voltage to earth: 25 V
Output items DC voltage, DC current, resistance (simulated output)
Output range DC voltage: -0.100 0 V to +5.300 0 V (setting resolution: 0.1 mV)
DC current:
5 mA range: -5.000 0 mA to +5.000 0 mA, Setting resolution: 0.1 μA
1 mA range: -1.000 00 mA to +1.000 00 mA, Setting resolution: 0.01 μA
250 μA range: -250. 00 μA to +250.00 μA, Setting resolution: 0.01 μA
50 μA range: -50. 000 μA to +50. 000 μA, Setting resolution: 0.001 μA
Resistance: 10 Ω to 1 MΩ, Setting resolution: 6 digits
Output accuracy DC voltage: 5 V range, ±0.035% of setting ± 800 μV
DC current:
5 mA range: ±0.050% of setting ± 4.0 μA
1 mA range: ±0.050% of setting ± 800 nA
250 μA range: ±0.050% of setting ± 200 nA
50 μA range: ±0.050% of setting ± 40 nA
Other Self diagnostic, switch output terminals, estimate target connection, cancel offset
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 280 g (9.9 oz)
Included accessories None

Hioki U8794 VIR Generator Unit

Request Callback

₹ 387000 / Piece Get Latest Price

Product Brochure
PhaseSingle Phase
Input Voltage240 V AC
Operating Temperature25 V
UsageVarious simulation tests instead of sensor output
Size106 mm (4.17 in) W x 19.8 mm (0.78 in) H x 196.5 mm (7.74 in) D
Weight280 g (9.9 oz)
Model NumberU8794
BrandHioki
Number of Channels8
Features:
  • As an inspection device of the ECU, it is ideal for generating simulation signals of various sensors, inspection of electronic parts, equipment maintenance
  • DC voltage, DC current, and resistance simulation output
  • In resistance generation, the voltage to be connected is measured, the output current is calculated from the set resistance value, and simulated output
  • Used in combination with Memory HiCorder series MR8740T (not available in other models)
  • Isolation between each output channel and between channel and chassis
  • Generation unit can be used for various simulation tests instead of sensor output