High Precision Power Meters 3 Phase

of a wide range of products which include hioki pw8001 power analyzer and hioki pw3336 power meter.

Hioki PW8001 Power Analyzer

Request Callback

₹ 700000 / Piece Get Latest Price

Product Brochure
Model Name/NumberPW8001
Usage/ApplicationLaboratory Use
Display TypeDigital
PhaseThree Phase
ColorWhite
Measurement lines 1-phase-2-wire, 1-phase-3-wire, 3-phase-3-wire, 3-phase-4-wire
No. of PW8001 input units Max. 8 units (mix and match)
Type of input unit U7001 2.5 MS/s INPUT UNIT
U7005 15 MS/s INPUT UNIT
Measurement frequency band U7001: DC, 0.1 Hz to 1 MHz
U7005: DC, 0.1 Hz to 5 MHz
Sampling U7001: 2.5 MHz, 16-bit
U7005: 15 MHz, 18-bit
Data update rate 1 ms, 10 ms, 50 ms, 200 ms
Accuracy for power (U7001) 50/60 Hz: 0.02% of reading + 0.05% of range
DC: 0.02% of reading + 0.05% of range
50 kHz : 0.4% of reading + 0.1% of range
Accuracy for power (U7005) 50/60 Hz : 0.01% of reading + 0.02% of range
DC : 0.02% + 0.03% of reading of range
50 kHz: 0.15% of reading + 0.05% of range
Measurement range Voltage: 6 V, 15 V, 30 V, 60 V, 150 V, 300 V, 600 V, 1500 V
Current: (Probe1) 40 mA to 2 kA, (Probe2) 100 mA to 50 kA
(Probe1 : Hioki's high-accuracy current sensor interface supports automatic identification and phase shift correction.
Probe 2: BNC I/F only for U7001)

Hioki PW3336 Power Meter

Request Callback

₹ 46000 / Piece Get Latest Price

Product Brochure
PhaseThree Phase
InterfacesRS-232C / LAN standard, (-01/-03 model also includes GP-IB)
Measurement range[Voltage] 0.15 V to 1000 V AC/DC
Input resistance (50/60 Hz)[Voltage] 2
Frequency characteristicsDC, 0.1 Hz to 100 kHz
Measurement lines Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, (voltage / current measurement range set for each wiring mode)
Measurement items Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Efficiency, Current integration, Active power integration, Integrated time, Voltage waveform peak value, Current waveform peak value, Voltage crest factor, Current crest factor, Time average current, Time average active power, Voltage ripple factor, Current ripple factor
Harmonic parameters Synchronization frequency range: 10 Hz to 640 Hz, Analysis order up to 50th
Harmonic voltage RMS value, Harmonic current RMS value, Harmonic active power, Total harmonic voltage distortion, Total harmonic current distortion, Voltage fundamental waveform, Current fundamental waveform, Active power fundamental waveform, Apparent power fundamental waveform, Reactive power fundamental waveform, Power factor fundamental waveform (displacement power factor), Voltage current phase difference fundamental waveform, Interchannel voltage fundamental wave phase difference, Interchannel current fundamental wave phase difference, Harmonic voltage content % , Harmonic current content % , Harmonic active power content %
(The following parameters can be downloaded as data during PC communication but not displayed: Harmonic voltage phase angle, Harmonic current phase angle, Harmonic voltage current phase difference)
Measurement range (*1) [Voltage] 0.15 V to 1000 V AC/DC

[Current]
Direct input: 2 mA to 65 A AC/DC
For AC/DC measurement using the CT6877A as an example: 4 A to 2000 A AC/DC (typical accuracy ±0.348%)
For AC measurement using the CT9667-01 as an example: 10 A to 5000 A AC (typical accuracy ±2.6%)
Integration measurement
(Integration time up to 10,000 hours)
[Current] No.of displayed digits: 6 digits (from 0.00000 mAh, Polarity-independent integration and Sum value)
[Active power] No.of displayed digits: 6 digits (from 0.00000 mWh, Polarity-independent integration and Sum value)
Input resistance (50/60 Hz) [Voltage] 2 MΩ, [Current] 1 mΩ or less (direct input)
X

Contact Us

Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India

Get Directions
Send Email
Share: