High Precision Power Analyzers

of a wide range of products which include hioki pw3390 power analyzer, hioki pw6001 power analyzer, hikoi vt1005 ac high voltage divider and hioki vt1005 - ac/dc high voltage divider.

Hioki PW3390 Power Analyzer

Request Callback

₹ 1500000 / Piece Get Latest Price

Product Brochure
Model Name/NumberPW3390
Usage/ApplicationLaboratory Use
Display TypeDigital
PhaseThree
Accuracy1 year Accuracy Warranty
ColorWhite
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel
Measurement items Frequency, RMS voltage, voltage mean value rectification RMS equivalent, voltage AC component, voltage simple average, voltage fundamental wave component, voltage waveform peak +, voltage waveform peak -, voltage total harmonic distortion, voltage ripple factor, voltage unbalance factor, RMS current, current mean value rectification RMS equivalent, current AC component, current simple average, current fundamental wave component, current waveform peak +, current waveform peak -, current total harmonic distortion, current ripple factor, current unbalance factor, active power, apparent power, reactive power, power factor, voltage phase angle current phase angle, power phase angle, positive-direction current magnitude, negative-direction current magnitude, sum of positive- and negative-direction current magnitude, positive-direction power magnitude, negative-direction power magnitude, sum of positive- and negative-direction power magnitude, efficiency, loss
Current integration, active power integration
PW3390-03 only: Torque, Rotation, Frequency, Slip, or Motor power
Harmonic measurement Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order
Noise measurement Number of channels: 1 ch (select one channel from CH1 to CH4),
Maximum analysis frequency: 200 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz
Motor Analysis
(PW3390-03 only)
Input: 3 ch (CH A, CH B, CH Z), Measurement parameters: Voltage, torque, rotation rate, frequency, slip, and motor power
Measurement range Voltage range: 15 to 1500 V, 7 ranges
Current range: 0.1 A to 20 kA (depends on current sensor)
Effective measuring power range 0.0150 W to 39.600 MW (determined automa

Hioki PW6001 Power Analyzer

Request Callback

₹ 1900000 / Piece Get Latest Price

Product Brochure
Model Name/NumberPW6001
Usage/ApplicationLaboratory Use
Display TypeDigital
PhaseThree Phase
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Number of input channels Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and current input
(Voltage measurement unit: Photoisolated input, resistance voltage divider, Current measurement unit: Isolated input from current sensor)
Measurement items Voltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)
Harmonic measurement: Harmonic active power, select calculation order
from 2nd order to 100th order
Waveform recording: Voltage and current waveforms/ Motor pulse: Always 5 MS/s
Motor waveforms: Always 50 kS/s, 16 bits
Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor
waveforms)
Motor analysis (PW6001-11 to -16 only): Voltage, Torque, Rotation, Frequency, Slip, or Motor output
Measurement range Voltage range: 6 to 1500 V, 8 ranges
Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor)
Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor)
Power range: 2.40000W to 4.50000MW (depends on combination of voltage and current range)
Frequency range: 0.1 Hz to 2 MHz
Basic accuracy Voltage: ±0.02 % rdg. ±0.02 % f.s.
Current: ±0.02 % rdg. ±0.02 % f.s.
Active power: ±0.02 % rdg. ±0.03 % f.s.
Synchronization frequency range Power measurement: 0.1 Hz to 2 MHz
Harmonic measurement: 45 Hz to 66 Hz (IEC standard mode), 0.1 Hz to 300 kHz (Wideband mode)
Frequency band DC, 0.1 Hz to 2 MHz

Hikoi VT1005 Ac High Voltage Divider

Request Callback

₹ 45000 / Piece Get Latest Price

Product Brochure
Colorwhite
SeriesVT1005
Resistance10 Ohm
Power Rating1/8W
Usage/ApplicationIndustrial
Mounting typeSMD
Maximum rated voltage 5000 V rms, ±7100 V peak (*1)
Maximum rated voltage
(line-to-ground)
No measurement category: 5000 V AC/DC (*2)
Measurement category II: 2000 V AC/DC (*3)
Measurement category III: 1500 V AC/DC (*4)
Voltage dividing ratio 1000:1
Measurement accuracy ±0.08%(DC), ±0.04%(50/60 Hz), ±0.17% (50 kHz)
Frequency
flatness
Band where amplitude falls within ±0.1% range: 200 kHz (typical)
Band where phase falls within ±0.1° range: 500 kHz (typical) (*5)
Measurement bandwidth DC to 4 MHz (Amplitude and phase accuracy specified up to 1 MHz)
Common-mode voltage
rejection ratio (CMRR)
50 Hz/60 Hz: 90 dB(Typical)
100 kHz: 80 dB (Typical)
Measurement method Differential input
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Storage temperature and humidity range −20°C to 60°C (-4°F to 140°F), 80% RH or less (non-condensing)
Standards Safety: EN 61010
EMC: EN 61326 Class A

Hioki VT1005 - AC/DC High Voltage Divider

Request Callback

₹ 414000 / Piece Get Latest Price

Product Brochure
WeightApprox. 2.2 kg (77.6 oz.)
Resistance100 Ohm
Power Rating1/8W
Usage/ApplicationElectrical Industry
Maximum rated voltage5000 V rms, +-7100 V peak (*1)
Power supply100 V to 240 V AC (50/60 Hz)
DimensionsApprox. 195.0 mm (7.68 in) W x 83.2 mm (3.28 in) H x 346.0 mm (13.62 in) D mm
Inverters used in rail and power system applications convert high-voltage power. To measure the efficiency of such conversions, it’s necessary to measure voltages of 1000 V and above. The VT1005 divides voltages of up to 5000 V and outputs them to a power analyzer.In order to measure the efficiency of high-efficiency inverters with a high degree of precision, you need to be able to accurately measure power from DC to high frequencies. Thanks to its excellent frequency flatness, the VT1005 makes possible accurate measurement at frequencies ranging from the fundamental wave to switching-frequency components.