Data Loggers Wireless Bluetooth Radio

Our product range includes a wide range of hioki lr8450-01 wireless lan memory hilogger, hioki lr8512 wireless pulse logger, hioki lr8515 wireless voltage logger and hioki lr8514 wireless humidity logger.

Hioki LR8450-01 Wireless Lan Memory Hilogger

Request Callback

₹ 228818 / Piece Get Latest Price

Product Brochure
Number of channels12
ApplicationIndustrial
InterfaceWiFi
TypeWireless
Display TypeLED
Parameters configurableTemperature, Power, Voltage, Current, Humidity

Minimum order quantity: 1 Piece

Accuracy guaranteed: 1 year
Max. number of connectable modules 4 plug-in modules + 7 wireless modules
Connectable modules
(Plug-in modules)
See [Options] > [Plug-in modules]
Connectable modules
(Wireless modules)
See [Options] > [Wireless modules]
No. of measurement channels Up to 120 ch with plug-in modules, up to 330 ch with plug-in modules and wireless modules
(U8555 and LR8535 can input up to 500 channels per module)
Pulse/logic input [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels)
[Adaptive input format] Non-voltage contact, open collector, or voltage input
[Count] 0 to 1000 M pulse, 1 pulse resolution
[Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000)
[Logic input] Records 1 or 0 for each recording interval
Recording intervals 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each module)
Data storage SD Memory Card/USB Drive (user-selectable)
(Only storage media sold by HIOKI are guaranteed for operation)
LAN interface 100BASE-TX / 1000BASE-T, DHCP, DNS support,
Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client
Wireless LAN interface IEEE 802.11b/g/n
Communications range: 30 m, line of sight
Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES
Usable channels: 1 to 11
Supported modes: Wireless module connectivity, access point, station
Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, Email transmission, NTP client
USB interface Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub))
Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer
SD card slot SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: ‌Z4001, Z4003
Display 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel)
Functions Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable)
Power supply [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter)
[Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max.
[External power] 10 to 30 V DC, 28 VA Max.
Dimensions and mass With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions)
With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions)
Included accessories

Hioki LR8512 Wireless Pulse Logger

Request Callback

₹ 36300 / Piece Get Latest Price

Product Brochure
Number of Channels4
Usage/ApplicationIndustrial
InterfaceDigital
Power Supply2 x AA alkaline batteries (LR6)
MemoryRecording Intervals: 0.1 sec to 30 sec, or 1 min to 60 min (16 selectable intervals)
ShapeSquare

Minimum order quantity: 1 Piece

Basic specificationsAccuracy guaranteed: 1 year
Functionality [Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Software can be downloaded free of charge from Google Play.)
*Communication range varies with the performance of the computer or tablet
(up to a line-of-sight distance of roughly 30 m)
[Used as logging module (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m
Number of channels 2ch (common GND)
Measurement items Integrating (cumulative/ Instant), Revolution, Logic (Records a 1/0 for each recording interval)
Supported input format Non-voltage “a” contact (always-open contact point), open collector, or voltage input (DC 0 to 50 V)
Measurement range [Totalization] 0 to 1000 M pulse, Max. resolution 1 pulse,
[No. of revolutions] 0 to 5000/n [r/s], Max. resolution 1/n [r/s]
Display items Measurement value, date, time, number of recorded data, maximum value, minimum value, and average value
Functions Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function
Recording [Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.1 to 30 sec, 1 to 60 min, 16 selections
Power source AC Adapter Z2003 (100 to 240 V AC, 50/60 Hz), AA alkaline batteries (LR6) ×2, External power 5 to 13.5 V DC (can also be supplied from USB bus power, with a conversion cable)
Continuous operating time
([Capacity] 500,000 data items for each channel) (23˚C)
2 months (Recording interval of 1 min, Bluetooth® OFF), 14 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.1 sec, during real-time measurement with the LR8410)
Dimensions and mass 85 mm (3.35 in) W × 61 mm (2.40 in) H × 31 mm (1.22 in) D, 95 g (3.4 oz) (excluding the battery)
Included accessories CD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves ×1, AA alkaline batteries (LR6) ×2, Connection cable L1010 ×2

Hioki LR8515 Wireless Voltage Logger

Request Callback

₹ 47010 / Piece Get Latest Price

Product Brochure
Number of Channels4
InterfaceDigital
Power SupplyZ2003 (100-240 V AC)
Memory500,000 data points per channel
Warranty1 year
ShapeSquare

Minimum order quantity: 1 Piece

Accuracy guaranteed: 1 year
Functionality [Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Software can be downloaded free of charge from Google Play.)
*Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m)
[Used as logging module (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m
Number of channels 2 ch (isolated; select voltage of thermocouple for each channel), Input terminals: M3 screw type terminal block
Measurement items Voltage/ Thermocouple (K, T)
Maximum input voltage ±50 V DC, Max. inter-channel voltage 60 V DC
Measurement range [Voltage] ±50 mV to ±50 V , Max. resolution 0.01 mV
[Thermocouple] -200 ˚C to 999.9 ˚C, Thermocouples (K, T), Max. resolution 0.1 ˚C
Measurement accuracy [Voltage] ±0.05 mV (50 mV range)
[Thermocouple] ±0.8 ˚C (Thermocouple K -100 ˚C to 999.9 ˚C)
*Reference junction compensation: Switchable between internal and external
*Reference junction compensation accuracy: ±0.5 ˚C
(When using internal compensation, add to thermocouple measurement accuracy.)
*Temperature characteristics: Add (measurement accuracy × 0.1) / ˚C to measurement accuracy.
Display items Measurement value, date, time, number of recorded data, maximum value, minimum value, and average value
Functions Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run
Recording [Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.1 to 30 sec, 1 to 60 min, 16 selections
Power source AC Adapter Z2003 (AC100 V to 240 V, 50 Hz/60 Hz), AA alkaline batteries (LR6) ×2, External power DC5 V to 13.5 V (can also be supplied from USB bus power, with a conversion cable)
Continuous operating time
([Capacity] 500,000 data items for each channel) (23˚C)
2.5 months (Recording interval of 1 min, Bluetooth® OFF), 7 days (Recording interval of 1 sec, Bluetooth® ON), 2 days (Recording interval of 0.1 sec, during real-time measurement with the LR8410)

Hioki LR8514 Wireless Humidity Logger

Request Callback

₹ 31800 / Piece Get Latest Price

Product Brochure
Number of Channels2
Warranty1 Year
BrandHioki
Model NumberLR8514
Dimensions85 mm (3.35 in) W x 61 mm (2.40 in) H x 31 mm (1.22 in)
Weight95 g

Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The Hioki LR8514 Wireless Humidity Logger provides easy, wireless collection of temperature and humidity data, and is the ideal tool for managing the environmental condition of production plants and agricultural sites.

  • High-precision, ±3% RH humidity sensor
  • Convenient for simultaneously recording and comparing temperature and humidity readings at 2 locations
  • Compact, two-channel model fits where other devices don’t
  • Download measurement data to a tablet or computer with Bluetooth® wireless technology
  • Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply)
  • Store 500,000 data points per channel

X

Contact Us

Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India

Get Directions
Send Email
Share: