Data Acquisition For R&D And Testing Applications

Providing you the best range of hioki mr8740t memory hicorder, hioki mr8847a memory hicorder, hioki mr8875 memory hicorder, hioki mr8880 memory hicorder, hioki mr6000 memory hicorder and hioki mr8827 memory hicorder with effective & timely delivery.

Hioki MR8740T Memory Hicorder

Request Callback

₹ 2200000 / Piece Get Latest Price

Product Brochure
Number of ChannelsMax. 108 ch analog
Usage/ApplicationLaboratory
Interface[LAN] 1000 BASE-T, 100 BASE-TX, 10 BASE-TX (2 port) (DHCP and DNS support, FTP server/cliant, HTTP s
Power Supply100 to 240 V AC, 50/60 Hz (400 VA max.)
MemoryTotal of 1 G Word installed, 16 MW/ch (when using 8966), 8 MW/ch (when using U8975 or MR8990), 4 MW/
Internal StorageSSD 480 GB
Number of input unitsMax. 27 slots
Max. allowable input400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without d
Max. rated voltage to earth300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit volt
Frequency characteristicsDC to 5 MHz (-3 dB, when using 8966)
Max. sampling speed20 MS/s, all ch simultaneous, external sampling: 10 MS/s
Removable storageUSB memory stick x8
Monitor outputVGA, HDMI, Display Port, Recommended resolution 1920 x 1080 dot or more
Dimensions and mass426 mm (16.77 in)W x 177 mm (6.97 in)H x 505 mm (19.88 in)D, 14.0 kg (493.8 oz) (main unit only)
Included accessoriesPower cord x1,Quick Start Manual (booklet) x1, Instruction Manual (detailed edition) (CD-R) x1, appl
Measurement ranges100 mV to 400 V f.s., 12 ranges, resolution : 1/2000 of range (when using 8966) 4 V to 200 V f.s., 6
The MR8740T (MR8740-50) is rack-mountable data acquisition system that delivers high-speed, multi-channel measurements over maximum of 108 channels. Generate simulated signals and record at the same time using plug-and-play input units, making the waveform recorder ideal for evaluating multi-signal devices such as vehicle electronic control units (ECU).

Hioki MR8847A Memory Hicorder

Request Callback

₹ 677325 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMR8847A
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Number of channels32 ch analog + 16 ch logic, or 20 ch analog + 64 ch logic (when used with built-in logic input + pl
Brand Hioki
Model MR8847A
Dimensions 351 mm (13.82 in) W x 261 mm (10.28 in) H x 140 mm (5.51 in) D
Weight 7.6 kg (268.1 oz)
Voltage 100 to 240 V AC, 10 to 28 V DC
Frequency 50 - 60 Hz
Display 10.4 inch TFT color LCD (SVGA, 800 x 600 dots)
Recording Speed 50 mm/s
Displayable Languages English, Japanese, Korean, Chinese
Number of slots 8
Hioki MR8847A Memory Hicorder are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, acceleration, and rotation due to complete isolation between channels and from each channel to the ground. The MR8847A delivers 20MS/s sampling, 16 isolated channels, and max. 1000V direct input, all housed in a tough and field-ready body to properly respond to the most challenging worksites from transformer substations to railway maintenance yards to paper and steel mills.

Key Features :
  • Supports a wide variety of measurements with a total of 13 plug-in modules
  • Generate and record with a single unit
  • Direct 1000 V high voltage input testing
  • High-speed sampling up to 20MS/s with fully isolated inputs
  • 16 analog + 16 logic channels to 64 logic + 10 analog channels
  • High-speed sampling with waveform judgment function
  • Soil-resistant construction strong against adverse working environments
  • Big buttons coated to withstand industrial oil and residue
  • Drop-in paper loading and one-touch setup, along with high-speed 50mm/sprinting

Hioki MR8875 Memory HiCorder

Request Callback

₹ 439600 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8875
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Basic specificationsAccuracy guaranteed: 1 year
Number of input units Up to 4 slots
Number of channels Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels
Note: For analog units, channels are isolated from each other and from the MR8875’s GND. For CAN unit ports or standard logic terminals or standard pulse terminals, all channels have common GND.
Measurement ranges
(20 div full-scale)
5 mV to 10 V/div , 11 ranges (when using the MR8901), 500 mV to 50 V/div , 7 ranges (when using the MR8905), resolution : 1/1250 of range
Max. rated voltage Between terminals: 150 V DC
Between terminal to earth: 100 V AC, DC (when using the MR8901)
Frequency characteristics DC to 100 kHz (-3 dB, when using the MR8901)
Time axis 200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible
Max. sampling rate [When using MR8901] 500 kS/s (2 μs period, all channels simultaneously)
[When using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval)
[When using MR8903] 200 kS/s (5 μs period, all channels simultaneously)
External sampling: 200 kS/s (5 μs period)
Measurement functions High-speed function (high speed recording), Real-time calculation between channels, FFT calculation, or other functions
Storage memory capacity Total 32 M-words (memory expansion: N/A, 8 MW each input unit)
Note: 1 word = 2 bytes, therefore 32 Mega-words = 64 Mega-bytes.
Note: Storage memory can be allocated depending on the number of channels used at each input unit
Removable storage SD card slot ×1, USB 2.0 memory
Display Touch-panel operation 8.4-inch SVGA-TFT color LCD (800 × 600 dots)
Communication interfaces LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send E-mail, command control)
USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with communication command, or file transfer SD card to PC), series A receptacle ×2 (USB memory, USB mouse/ key-board)
Power supply 1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA
2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with back light ON (AC adapter has priority when used in combination with battery pack), Charges while installed in the MR8875, recharging time: 3 hours
3) External DC Power: 10 to 28 V DC, 56 VA
Dimensions and mass 298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding input units and the Battery pack Z1003)
Reference data: 3.47 kg/ 122.4 oz (including the MR8901 ×4 units and the Battery pack Z1003)
Included accessories Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv, communication commands table, CAN Editor) ×1
LabVIEW and MATLAB support
Compatible models LabVIEW MATLAB script
MR8875 Available Available

Hioki Mr8880 Memory Hicorder

Request Callback

₹ 252500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8880
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Basic specificationsAccuracy guaranteed: 1 year
Number of channels 4 analog channels + 8 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
Measurement ranges
(10 div full-scale)
4 channels of voltage measurement; mode switchable between instantaneous waveform or RMS value, 10 mV to 100 V/div, 13 ranges, resolution: 1/640 of range
RMS value mode: 30 Hz to 10 kHz, Crest factor: 2
Max. rated voltage Between terminals: 600 V AC/DC, Between terminal to earth: 600 V AC/DC CAT III; 300 V AC/DC CAT IV
Frequency characteristics DC to 100 kHz (±3dB)
Time axis
(High-speed function)
100 µs to 100 ms/div, 10 ranges, Sampling period: 1/100 of range
Recording intervals
(Real-time function)
100 µs to 1 minute, 19 selections (simultaneous sampling in all channels)
Measurement functions High-speed function (high speed recording)
Real-time function (actual time recording)
Memory capacity 14-bits × 1M-words/ch (1 word = 2 bytes)
Removable storage CF card slot ×1 (Up to 2 GB), USB 2.0 memory ×1
Printing [Printer unit is option] 112 mm (4.41 in) × 18 m (59.06 ft), thermal paper roll, Recording speed : 10 mm (0.39 in)/sec
Note: Printing is not supported when using alkaline batteries
Display 5.7-inch VGA-TFT color LCD (640 × 480 dots)
Displayable languages English, Japanese, Chinese
Communication interfaces USB 2.0 mini-B receptacle × 1; Transfers files from the installed CF card or USB memory stick to a PC when connected, and External PC control
Power supply AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 45 VA (include AC adapter, when Real-time recording), 107 VA (include AC adapter, when Real-time recording and printing)
Battery pack Z1000: AC adapter has priority when used in combination with battery pack, recharge with AC adapter 3 hours, Continuous use 3 hours (with back-light ON)
LR6 (AA) alkaline batteries ×8, Continuous use 40 minutes, (with back-light ON, cannot be used with the Printer unit)
DC power supply: 10 to 28 V DC
Dimensions and mass 205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 1.66 kg (58.6 oz) (with the Battery pack installed)
When printer is combined - with main unit: 303 mm (11.93 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 2.16 kg (76.2 oz) (with the Battery pack installed)
Included accessories Instruction manual ×1, AC adapter Z1002 ×1, Alkaline battery box ×1, Strap ×1, USB cable ×1, Application disk (Wave viewer Wv, Communication commands table) ×1
LabVIEW and MATLAB support
Compatible models LabVIEW MATLAB script
MR8880-20 N/A N/A

Hioki MR6000 Memory Hicorder

Request Callback

₹ 1251595 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMemory Hicorder Mr6000
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Highest Measurement Capabilities and Fastest Transfer Rate in History
Country of Origin Made in India
Brand Hioki
Weight 6.5 kg (229.3 oz) (main unit only)
Model MR6000
Number of Input Units Max 8 units
Number of Channels Max. 32 analog channels (when using the U8975),or 128 logic channels (when using the 8973)
Max Allowable Input 400 V DC (when using the U8976),200 V DC (when using the U8975)
Storage Memory Capacity 1 G-words
Display 12.1 inch XGA-TFT color LCD (1024 x 768 dots)
Power Supply 100 to 240 V AC (50/60 Hz) (300 VA max.)
Dimensions 353 mm (13.9 in)W x 235 mm (9.25 in)H x 154.8 mm (6.09 in)D
The Hioki MR6000 Memory Hicorder overcomes all barriers to reach the new ground and meet challenges that are yet to be seen. World class specifications, operability, and design - Hioki's newest memory recorder has been re-engineered from top to bottom, delivering unprecedented performance that will change how you look at waveform recording 
Key Features :
  • High-speed 200 MS/s isolated testing (with High-Speed Analog Unit U8976Ax8)
  • Simultaneously measure up to 32 analog channels (with 4ch Analog Unit U8975x8)
  • Real-time saving of data of all 32 chat 1 MS/s (with SSD Unit U8332)
  • Highly-responsive touchscreen 
  • Memory Concierge: Easily search for the waveform you want to see with the waveform search function
  • Faster save times (1/10th the time required by legacy models)
  • Real-time digital filter calculation

Hioki MR8827 Memory Hicorder

Request Callback

₹ 954965 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8827
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the MR8827 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as trial runs after the scheduled maintenance of railway cars to verify for voltage command signals, motor current, car speed, and brake pressure.
Key Features• Generate and record waveforms with a single unit • Output previously recorded problematic waveforms and apply to devices under test to simulate potential issues• 32 analog + 32 logic channels to 28 analog + 64 logic channels• High-speed sampling up to 20MS/s with fully isolated inputs• Safe measurement with all isolated analog inputs• Large capacity memory of total 512M-words• Measure various system signals from high voltage to ultra low voltage simultaneously
Specifications:
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Max. Number of channels 32 ch analog + 32 ch logic, or 28 ch analog + 64 ch logic (when use with built-in logic input + plug-in logic unit 8973 × 2)
Number of slots 16 slots (Max. 16)
Number of logic channels 32 ch logic (logic probe terminal GND share a common GND with chassis) Built-in logic input not available when using DVM Unit MR8990 on slots 1, 2, 9, or 10.

[Limitation on using built-in logic input] (with logic measurement ON)
• Measurement resolution on slots 1, 2, 9, and slot 10 is limited up to 12 bits
• Cannot use Frequency Unit 8970 on slots 1, 2, 9, or 10
Measurement ranges (20 div full-scale) [Analog Unit 8966]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/100 of range (using 12-bit A/D)
[High Resolution Unit 8968]: 5 mV/div to 20 V/div, 12 ranges, resolution : 1/1600 of range (using 16-bit A/D)
Max. allowable input 400 V DC (using the 8966/8968)
Frequency characteristics DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968)
Time axis (Memory function) 5 µs to 5 min/div, 26 ranges, at 100 points/div resolution
Measurement functions Memory (high-speed recording), Recorder (real-time recording), X-Y recorder, FFT
Other functions Numerical calculation, Waveform processing, Waveform judgment (at Memory, or FFT function)
Memory capacity 128M-words/ch (using 4 Analog channels) to 16M-words/ch (using 32 Analog channels), Total capacity 512MW memory
Data storage media USB memory stick, CF card, Built-in SSD unit (option, 128GB) *Approx. 125 sec. when saving 100 MB of data
*Data of 100 MB in size can record 16,000 div waveforms across 32 channels.
Printing [Built-in A4-size printer option]: 216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
Display 10.4 inch TFT color LCD (SVGA, 800 × 600 dots)

Hioki MR8741 Memory Hicorder

Request Callback

₹ 1921325 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8741
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Basic specificationsAccuracy guaranteed: 1 year
Max. Number of channels 16 ch analog + 16 ch logic, or 10 ch analog + 64 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3)
Number of slots 8 slots (Max. 8)
[Limitation on number of slots] cannot use Current Unit 8971 When using the Logic Unit 8973: Max. 3
Number of logic channels 16 ch logic (Logic probe terminal GND share a common GND with chassis. ) on condition that DVM Unit MR8990 is used on slots 1 and 2, cannot use built-in logic input
[Limitation on using built-in logic input] (with logic measurement ON)
• Measurement resolution on slots 1 and 2 is limited up to 12 bits
• Cannot use Frequency Unit 8970 on slots 1 and 2
Measurement ranges (20 div full scale) 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966)
5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990)
Max. allowable input 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage)
Frequency characteristics DC to 5 MHz (-3 dB, when using 8966)
Time axis (MEMORY operation) 5 µs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000
Measurement functions Memory (high-speed recording), FFT, Recorder
Memory capacity 16 MW/ch (fixed), total of 256 MW installed
Removable storage USB memory stick (USB 2.0)
Display None (1 digital DVI terminal, 800 × 600 dots)
External interfaces [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
Power supply 100 to 240 V AC, 50/60 Hz (120 VA max.)
Dimensions and mass 350 mm (13.78 in)W × 160 mm (6.30 in)H × 320 mm (12.60 in)D, 5.4 kg (190.5 oz) (main unit only)
Included accessories Instruction manual ×1, Application disk (Wave viewer Wv, Communication commands table) ×1, Power cord ×1
LabVIEW and MATLAB support
Compatible models LabVIEW MATLAB script
MR8740 Available Available
MR8741 Available Available

Hioki MR8740 Memory Hicorder

Request Callback

₹ 1921325 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8740
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Accuracy guaranteed: 1 year
Max. Number of channels [Block I] 32 ch analog + 8 ch logic, or 29 ch analog + 56 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3)

[Block II] 22 ch analog + 8 ch logic, or 19 ch analog + 56 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3)
Number of slots [Block I] 16 slots (Max. 16)
[Block II] 11 slots (Max. 11)

[Limitation on number of slots] when using the Current Unit 8971: Max. 4,
When using the Logic Unit 8973: [Block I] Max. 3; cannot use slots 9 to 16
[Block II] Max. 3; cannot use slots 9 to 11
Number of logic channels [Block I] 8 ch logic (Logic probe terminal GND share a common GND with chassis. )
[Block II] 8 ch logic (Logic probe terminal GND share a common GND with chassis. )

[Limitation on using built-in logic input] applies to both Block I and Block II (with logic measurement ON)
- Measurement resolution on slots 1 and 2 is limited up to 12 bits
- Cannot use Frequency Unit 8970 on slots 1 and 2
- When using the DVM Unit MR8990 on slots 1 or 2: cannot use built-in logic input
Measurement ranges (20 div full scale) 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966)
5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990)
Max. allowable input 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage to earth 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage)
Frequency characteristics DC to 5 MHz (-3 dB, when using 8966)
Time axis (MEMORY operation) 5 µs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000
Measurement functions Memory (high-speed recording), FFT
Memory capacity 16 MW/ch (fixed), total of 864 MW installed
Removable storage USB memory stick (USB 2.0)
Display None (1 digital DVI terminal per block, 800 × 600 dots)
External interfaces [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
Power supply 100 to 240 V AC, 50/60 Hz (250 VA max.)
Dimensions and mass 426 mm (16.77 in) W × 177 mm (6.97 in) H × 505 mm (19.88 in) D, 10.8 kg (381.0 oz) (main unit only)
Included accessories Instruction manual × 1, Application disk (Wave viewer Wv, Communication commands table) × 1, Power cord × 1
LabVIEW and MATLAB support
Compatible models LabVIEW MATLAB script
MR8740 Available Available
MR8741 Available Available

Hioki MR8870 Memory Hicorder

Request Callback

₹ 114500 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Model Name/NumberMEMORY HiCORDER MR8870
Usage/ApplicationIndustrial
Packaging TypeBox
Country of OriginMade in India
Basic specificationsAccuracy guaranteed: 1 year
Number of channels 2 analog channels + 4 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range
Max. rated voltage Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II
Frequency characteristics DC to 50 kHz (-3 dB)
Time axis
(Memory mode)
100 µs to 5 min/div, 20 ranges,at 100 points/div resolution, three steps of time-axis magnification from ×2 to ×10, and 9 steps of time-axis compression from ×1/2 to ×1/1,000
Recording intervals
(RMS mode)
1 ms to 1 min., 16 settings, sampling period: 200 μs (fixed) (for AC voltage/current, 1,000 RMS values/sec.), envelope mode always on
Note: Only the maximum value and minimum value for each recording interval are recorded.
Measurement functions Memory recorder (high speed recording), RMS recorder (50/60 Hz, DC only)
Memory capacity 12-bits × 2M-words/ch (1 word = 2 bytes)
Removable storage CF card TYPE I slot ×1 (Up to 2 GB)
Display 4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
Displayable languages English, Japanese
Interfaces USB 2.0 mini-B receptacle ×1, Functionality: Connect the instrument to a PC to send files on the CF card to the PC. The instrument cannot be controlled from a PC.
Printer N/A
Power supply AC Adapter Z1005: 100 to 240 VAC (50/60 Hz) , 30 VA max. (when using the AC adapter and charging the 9780 with the instrument)
Battery Pack 9780: 3 VA, continuous operating time of approx. 2 hr. (25°C reference value; when used with the Z1005, the Z1005 takes priority), charging time of 200 min. using the AC adapter (25°C reference value) (option)
External DC power: 10 to 16 V, 10 VA max. (connection cord of 3 m or less is available by special-order)
Dimensions and mass 176 mm (6.93 in)W × 101 mm (3.98 in)H × 41 mm (1.61 in)D, 600 g (21.2 oz) (with the Battery pack 9780 installed)
Included accessories Instruction manual ×1, Measurement guide ×1, AC adapter Z1005 ×1, Strap ×1, USB cable ×1, Application disk (Dedicated program for the MR8870) ×1, Protection sheet 9809 ×1
LabVIEW and MATLAB support
Compatible models LabVIEW MATLAB script
MR8870-20 N/A N/A
X

Contact Us

Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India

Get Directions
Send Email
Share: