Offering you a complete choice of products which include hioki lr5041, lr5042, lr5043 voltage logger, hioki lr5031 instrumentation logger, hioki lr5091 communication adapter, hioki lr5092 data collector, hioki lr5001 humidity logger and hioki lr5011 temperature logger.
₹ 50000 / Piece Get Latest Price
| Interface | Infrared optical communications |
| Power Supply | LR6 (AA) Alkaline battery |
| Ip Rating | IP54 |
| Measurement items | DC voltage 1ch |
| Dimensions and mass | 79 mm (3.11 in) W x 57 mm (2.246 in) H x 28 mm (1.10 in) D, 105 g (3.7 oz) |
Minimum order quantity: 59 Piece
| LR5041 | LR5042 | LR5043 | ||||
| Measurement items | DC voltage 1ch | DC voltage 1ch | DC voltage 1ch | |||
| Measurement range | -50.00 to 50.00 mV | -5.000 to 5.000 V | -50.00 to 50.00 V | |||
| Accuracy | ±0.5 %rdg. ±5 dgt. | |||||
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data | |||||
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections | |||||
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
|||||
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
|||||
| Other functions | Pre-heat function (requires external power supply during use of function), Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced | |||||
| Waterproof and dust-proof | IP54 (EN60529) (with connection cable connected, but not including cable tip) | |||||
₹ 17859 / Piece Get Latest Price
| Interface | Infrared optical communications with LR5091, LR5092-20 |
| Power Supply | LR6 (AA) Alkaline battery |
| Memory | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
| Ip Rating | IP54 |
| Dimensions and mass | 79 mm (3.11 in) W x 57 mm (2.246 in) H x 28 mm (1.10 in) D, 105 g (3.7 oz) |
Minimum order quantity: 34 Piece
| Measurement items | DC current (1 ch), for Instrumentation | |||||
|---|---|---|---|---|---|---|
| Measurement range | -30.00 to 30.00 mA | |||||
| Accuracy | ±0.5 %rdg. ±5 dgt. | |||||
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data | |||||
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections | |||||
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
|||||
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
|||||
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced | |||||
| Waterproof and dust-proof | IP54 (EN60529) (with connection cable connected, but not including cable tip) | |||||
| Interfaces | Infrared optical communications with LR5091, LR5092-20 | |||||
₹ 4199 / Piece Get Latest Price
| Power | USB bus power |
| Communication method | Between data loggers: Infrared communication With PC: USB 2.0 |
| Included accessories | USB cable (1 m) x1, CD (Application software "LR5000 Utility") x1 |
| Function | Transfer data from a data logger to a PC Send settings and the time from a PC to a data logger. |
| Function | Transfer data from a data logger to a PC Send settings and the time from a PC to a data logger. |
|---|---|
| Communication method | Between data loggers: Infrared communication With PC: USB 2.0 |
| Display | N/A |
| Internal memory (capacity of data) | N/A |
| Removable storage media | N/A |
| Power supply | USB bus power |
| Dimensions and mass | 83 mm (3.27 in) W × 61 mm (2.40 in) H × 19 mm (0.75 in) D, 43 g (1.5 oz) |
| Included accessories | USB cable (1 m) ×1, CD (Application software "LR5000 Utility") ×1 |
₹ 40000 / Piece Get Latest Price
| Operating System | For Windows |
| Download Option | Free Download Available |
| Model Number | LR5092 |
| Voltage | DC 3 V (LR6 (AA) Alkaline battery x2) |
| Dimensions and mass | 91 mm (3.58 in) W x 141 mm (5.55 in) H x 31 mm (1.22 in) D, 215 g (7.6 oz) (excluding batteries and |
| Function | Send data from a data logger to the internal memory or an SD card, then display a graph. Send settings and the time from the internal memory or SD card to a data logger. Send data from a data logger to a PC. Send settings and the time from a PC to a data logger. |
|---|---|
| Communications method | Between data loggers: Infrared communications With PC: USB 2.0 |
| Display | Data logger setting conditions Collected data (as list, graph, values, etc.) |
| Internal memory (capacity of data) | 60,000 data elements ×16ch (instantaneous value mode) 15,000 data elements ×16ch (statistical value mode) Data logger settings (max. 1 set) |
| Removable storage media | SD memory card Save data and max. 16 items configuration |
| Power supply | DC 3 V (LR6 (AA) Alkaline battery ×2) USB bus power (12 hours or 500 times of data collection) |
| Dimensions and mass | 91 mm (3.58 in) W × 141 mm (5.55 in) H × 31 mm (1.22 in) D, 215 g (7.6 oz) (excluding batteries and SD memory card) |
| Included accessories | Instruction manual ×1, Operation guide ×1, LR6 (AA) Alkaline battery ×2, USB cable (1 m) ×1, CD (Application software "LR5000 Utility") × 1 |
₹ 23000 / Piece Get Latest Price
| Number of Channels | 4 |
| Interface | Infrared optical communications |
| Power Supply | LR6 (AA) Alkaline battery x 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minut |
| Memory | Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch |
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
| Brand | Hioki |
| Model | LR5001 |
| Measurement items | Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor) | |||||
|---|---|---|---|---|---|---|
| Measurement range | Temperature: -40.0°C to 85.0°C, Humidity: 0 to 100% RH at sensor environment | |||||
| Basic accuracy | [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) [Humidity] : ±5 % rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh) Note: Basic accuracy is typical value, refer to the detailed catalog |
|||||
| Storage capacity | Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch | |||||
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections | |||||
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
|||||
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
|||||
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement) |
|||||
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) | |||||
₹ 15500 / Piece Get Latest Price
| Number of Channels | 4 |
| Interface | Infrared optical communications |
| Memory | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
| Ip Rating | IP54 |
| Brand | Hioki |
| Brand | LR5011 |
| Power Supply | LR6 (AA) Alkaline battery x 1, Battery life: Approx. 2 years (Instantaneous recording, with 1-minute |
| Measurement items | Temperature 1ch (with optional sensor) | |||||
|---|---|---|---|---|---|---|
| Measurement range | -40.0°C to 180.0°C Depends on measurement range of sensor |
|||||
| Basic accuracy | ±0.5°C (main unit + sensor accuracy, at 0.0 to 35.0°C) Note: Basic accuracy is typical value, refer to the detailed catalog |
|||||
| Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data | |||||
| Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections | |||||
| Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
|||||
| Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
|||||
| Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced | |||||
| Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) | |||||
Shallu (Owner)
Amigos Scientific Solutions
Sn.19, Gali 7 Number School
Ambala - 134003, Haryana, India